Continuous vs Peak Torque: Sizing Joint Actuators for 24/7 Duty Cycles
A practical method for sizing joint actuators from the duty cycle rather than from the peak torque headline: RMS torque calculation, thermal derating for enclosure ambient and altitude, a worked 40-second inspection cycle, and a comparison of continuous torque, peak torque, backlash and bus options across 48 V and 72 V joint modules.
Most joint actuators are sold on peak torque and bought on continuous torque. The gap between those two numbers is where field failures live: a joint that delivers 431 N·m for three seconds in a demo will not survive 38 N·m RMS for 8,000 hours in a fab corridor unless the thermal side of the design was checked first. The method is not complicated, but it has to be run before the gearbox is ordered, not after the first over-temperature trip.
Start from the duty cycle, not the peak
A duty cycle is a short list of torque levels and the time spent at each one. Collapse it into a single number - the root-mean-square torque - and compare that number, not the peak, against the continuous rating of the joint. Copper loss scales with current squared and therefore roughly with torque squared, so the RMS value is the thermal equivalent of the whole cycle.
T_rms = sqrt( (T1²·t1 + T2²·t2 + ... + Tn²·tn) / (t1 + t2 + ... + tn) )
- Short peaks are absorbed by winding mass. If a peak lasts less than the winding thermal time constant - typically 30 s to several minutes on a framed joint - it contributes little to average heating. This is also why a 20 s bench test proves nothing about a 24/7 installation.
- Sustained dwell torque is the hidden problem. Holding a payload against gravity at 25 N·m for 30 s out of every 40 s heats the winding as effectively as a much larger transient, and it is the term most often left out of a hand calculation.
- Standstill is not free. A servo holding position at zero speed draws continuous current. A spring-applied brake that carries the static load removes that loss, at the cost of a brake sized for the load with a safety factor and a release circuit that fails safe.
What a joint datasheet actually tells you
Continuous stall torque is defined at a stated ambient, mounting and cooling condition - usually natural convection, horizontal flange, 25 to 40 °C. Those qualifiers are not marketing: a joint rated 54 N·m on a bare bench is a different component bolted inside an insulated enclosure at 55 °C. Read the qualifier before the number, and ask for the derating curve rather than a single figure.
| Model | Ratio | Continuous torque (output) | Peak torque | Rated speed | Mass | Bus / feedback |
|---|---|---|---|---|---|---|
| RU-JTM-55-066-96-107-D24 | 1:31 | 55 N·m | 165 N·m | 96 rpm | - | 24 V DC, RS485 encoder, <3 arcmin |
| RU-JTM-90-282-030-54-D48 | 1:100 | 54 N·m | drive-limited | 30 rpm | 1.5 kg | 48 V DC, CAN, 24-bit dual absolute, <20 arcsec |
| RU-JTM-90-065-110-90-D72-E | 1:30 | 90 N·m | 431 N·m | 65 rpm (110 max) | 1.9 kg | 72 V DC, EtherCAT |
| RU-JTM-120-150-135-102-D72-E | 1:18 | 102 N·m | 418 N·m | 135 rpm (300 max) | 3.0 kg | 72 V DC, EtherCAT |
Three things in that table are worth reading carefully. First, peak torque is usually limited by the drive current and the reducer's momentary rating rather than by the magnets, which is why the peak-to-continuous ratio differs between models (4.8x on the 90 mm 650 W unit, 4.1x on the 120 mm 1.5 kW unit). Sizing a peak requirement without checking available drive current is a common way to discover the limit in commissioning. Second, backlash and repeatability are different numbers: <3 arcmin on the cycloidal-pinwheel 55 mm unit and <20 arcsec on the harmonic 90 mm unit support different control loop bandwidths and different inspection accuracies. Third, mass belongs in the calculation because the actuator is usually the payload - torque per kilogram is what survives the arm's own dynamic budget.
Worked example: sizing a 24/7 inspection axis
Take a vertical inspection axis on a mobile platform: 12 kg tool head, 0.6 m stroke, 40 s cycle, continuous operation. The measured torque profile is four phases - accelerate upward at 90 N·m for 3 s, dwell and inspect at 25 N·m for 30 s, decelerate at 70 N·m for 3 s, return downward (gravity assisted) at 20 N·m for 4 s.
| Phase | Duration | Torque demand | T²·t |
|---|---|---|---|
| Accelerate upward | 3 s | 90 N·m | 24,300 |
| Dwell / inspect | 30 s | 25 N·m | 18,750 |
| Decelerate upward | 3 s | 70 N·m | 14,700 |
| Return downward | 4 s | 20 N·m | 1,600 |
| Total | 40 s | 59,350 |
The RMS torque is sqrt(59,350 / 40) = 38.5 N·m. Against the 54 N·m continuous rating of the 90 mm, 48 V module that is a 1.4x margin at 25 °C. If the axis sits inside an enclosure at 55 °C, apply the vendor derating before committing: at 85% of nominal the usable continuous torque falls to roughly 46 N·m - still above 38.5 N·m, but no longer a comfortable margin, and the defensible move is up to the 90 N·m continuous unit. Peak demand of 90 N·m is not the constraint here: with 431 N·m available, the joint is oversized 4.8x on peak and correctly sized on thermal.
Check speed separately, because torque and speed are sized by different limits. A 30 rpm output gives 180 °/s - adequate for a dwell-and-inspect cycle, not for a 0.6 m move in under a second. The 65 rpm unit (110 rpm maximum) buys the faster stroke at the cost of a larger frame and a 72 V bus. Neither answer is wrong; the point is that the duty cycle decides which one is right.
Environment derating: ambient, altitude and the enclosure you forgot
For rotary axes built around a servo motor plus gearbox rather than an integrated joint, the same thermal logic applies, with environment added on top. Semiconductors, outdoor telecom and defence platforms share three modifiers: elevated local ambient (the inside of a tool enclosure, not the room), altitude, and the fact that IP67 sealing trades convection for conduction.
| Model | Continuous torque | Peak torque | Rated speed | Protection | Max altitude | Feedback |
|---|---|---|---|---|---|---|
| JGSM-80C100 (80 mm, 1 kW) | 3.18 N·m | 9.54 N·m | 3,000 rpm (5,100 max) | IP67 | 6,000 m | resolver, with brake |
| JGSM-150F280 (150 mm, 2.8 kW) | 13.4 N·m | 40.2 N·m | 2,000 rpm (3,300 max) | IP67 | 6,000 m | resolver, no brake |
Both frames are rated -40 to +85 °C with a 3x torque overload and a resolver instead of an optical encoder, which matters in vibration and in contamination - a resolver has no disc to scratch. The altitude rating carries a capacity reduction requirement above 2,000 m, because both air cooling and insulation clearance degrade with thinner air. On a mobile platform the honest derating is usually the enclosure ambient plus the heat the drive and gearbox add inside that volume, not the cleanroom setpoint.
A short checklist before any joint order is released:
- Compute RMS torque from the real cycle, including dwell and return phases.
- Confirm the continuous rating is quoted at an ambient at least as high as the enclosure's.
- Check peak torque against available drive current, not just the reducer's momentary limit.
- Size the brake for the static load with a safety factor, and verify it engages on power loss.
- Check backlash and repeatability against the inspection or pointing accuracy, not against the gearbox catalogue headline.
- Verify cleanliness, outgassing and lubricant compatibility with the supplier for cleanroom use - a general IP rating says nothing about particle shedding.
The general lesson from a fab floor is that reliability is a specification, not a promise. Actuators that survive there are not the ones with the largest peak number; they are the ones whose thermal margin, backlash and feedback were matched to a duty cycle that somebody actually calculated.

Joint Motor 90 · 650W
90 N·m continuous stall, 431 N·m peak, 1:30 ratio, EtherCAT, -40 to +85 °C
View details →
Joint Motor 120 · 1.5kW
102 N·m continuous, 418 N·m peak, 1:18 ratio, 300 rpm max, EtherCAT
View details →
Cycloidal Joint Motor 55 · 660W
55 N·m output, 165 N·m peak, backlash under 3 arcmin, 24 V DC
View details →